Eight GPUs requested, six free. Guess what the default Kubernetes scheduler does.
Starts six of them and leaves two pods pending, every time. Which is a lovely way to open, because Daniel's prompt this week is basically asking for the episode he wishes existed before anyone buys their first rack of GPUs.
He wants the foundational walkthrough. If you're standing up your first GPU farm, what do you need to know — the scheduling and orchestration side, so Slurm, Kubernetes with the NVIDIA GPU Operator, Ray, and then the communication libraries living underneath all of that, NCCL and its relatives. And then the two scenarios everyone actually hits: can you mix AMD and NVIDIA in one cluster at all, and if you stay with one vendor, what happens when your cluster is a museum of different GPU generations.
The first thing to internalize is that this is not one problem. It's two, stacked.
Two problems. Separate failure modes. My favourite kind of architecture.
The scheduler decides which GPUs a job gets and when it gets them. The collective library decides how fast those GPUs can talk to each other once they're assigned. And here's the trap: a cluster can have perfect scheduling and terrible throughput, because the communication layer quietly fell back to TCP over Ethernet instead of RDMA over InfiniBand. Nobody tells you. It just runs slow.
And the reverse.
You can have a beautifully wired NVLink domain, everything within one switch, and it's useless because the scheduler handed your job six of the eight GPUs it asked for. The hardware is pristine and the job is standing in the doorway holding its coat.
So before we get into any product names — the concept that makes all of this make sense is all-or-nothing allocation. Gang scheduling, in the Kubernetes sense of the word.
Yes, and I want to flag the terminology trap early, because it catches people who come from both sides. In Slurm's documentation, "gang scheduling" means time-slicing — jobs take turns on the same resources, each one suspended while another runs. In Kubernetes, "gang scheduling" means all-or-nothing placement. Same two words, opposite instincts.
A Slurm veteran asking for gang scheduling in Kubernetes is asking for something Slurm gave him for free.
And why does it matter so much? Because distributed training synchronizes gradients across every rank. AllReduce, All-to-All — every GPU in the job has to participate in every step. A job spanning five hundred and twelve GPUs cannot make progress if five hundred eleven of them are running and the last one is sitting in a queue. It's not slower without the last GPU. It's stopped.
It's a rowboat with one oarsman short. Everyone else paddles, boat goes in circles.
So let's take the top layer, the scheduler, because it's honestly the friendlier of the two problems. Slurm first. Slurm is a centralized C implementation, and the architecture is refreshingly boring. There's a controller, slurmctld, which is the brain. There's a daemon on every compute node, slurmd. And there's slurmdbd, which is the accounting database, MySQL or MariaDB backed, and it's what powers the fair-share system.
Fair-share being the thing that decides my job runs before the person who's been hogging the machine all month.
That's the one. Multi-factor priority — how long a job has been waiting, partition priority, quality of service, and a hierarchical fair-share that decays over time. So your department's historical usage counts against you, but old usage counts less than recent usage. It's a very human system. It's designed for the reality that researchers will absolutely monopolize a cluster if you let them.
I respect a scheduler that assumes the worst about us.
And Slurm's core strength is that the allocation is atomic. When your job is admitted, all of its tasks get resources at once or the job doesn't start. That's native. You don't install anything for that — it's how the allocation works. Plus backfill optimization, so smaller short jobs can jump ahead into gaps as long as they don't delay anyone's earliest start. The claimed numbers on the control plane are thousands of job submissions per second with sub-millisecond dispatch latency, on clusters past a hundred thousand CPU and GPU cores.
Sub-millisecond dispatch. Somewhere a Kubernetes admin is laughing bitterly into his etcd.
That's the real comparison point, actually. Kubernetes control loops are built around declared state — you say what should exist, and controllers reconcile the world toward it. That's brilliant for services. It's a different muscle than a queue-based batch system, where the question is "of the ten thousand things people want right now, which one runs next."
And Slurm's weaknesses, before you write it a love letter.
It assumes static infrastructure. No native cloud VM autoscaling, no spot-instance lifecycle, no ephemeral disk that appears and disappears. Multi-tenancy is done through host-level POSIX users and LDAP or Kerberos, which works but it's rigid. And it's a poor fit for HTTP-serving inference — Slurm is fundamentally a batch animal. You don't ask a queue manager to keep a web service alive through a traffic spike.
Although — containers on Slurm. People do run containerized jobs under it.
Through NVIDIA's Enroot and the Pyxis plugin, and the reason that combination exists is sensible: it lets you run unprivileged containers on the compute nodes without a Docker daemon running as root on every machine. On an HPC cluster, where the nodes are precious and the users are creative, "no privileged daemon on the compute nodes" is not a nicety, it's the whole security model.
Kubernetes, then. Which is where our six-of-eight story lives.
The starting point for GPU nodes is the NVIDIA GPU Operator, and what it does is automate everything NVIDIA you'd otherwise bake into a custom OS image. The drivers, the Kubernetes device plugin, the NVIDIA container runtime, node labelling, DCGM-based monitoring. Install is a Helm chart. The practical payoff is that you can use one standard OS image for both your CPU nodes and your GPU nodes, because the operator injects all the NVIDIA machinery after the node joins.
And the device plugin is what makes a GPU visible as a schedulable resource.
It exposes GPUs as the nvidia.com slash gpu resource. It supports CUDA time-slicing and MPS for sharing one GPU across multiple workloads. But I'll give NVIDIA credit for honesty here — the device plugin's own README lists what it's missing. Comprehensive GPU health checking. GPU cleanup features. They wrote the gaps down themselves.
A README that admits its shortcomings. Refreshing, in a landscape of launch videos.
Now, the gap. Vanilla kube-scheduler places one pod at a time. It does not know that eight pods belong to one training job. The canonical failure from the CNCF's own whitepaper: your job needs eight GPUs, six are free, so the default scheduler cheerfully starts six pods and leaves two pending. Those six GPUs now sit idle, held by a job that cannot run. And if a few partial jobs each hold a slice, you can deadlock the whole node pool — GPUs allocated, nothing executing.
GPUs busy doing nothing. The most expensive screensaver in the datacenter.
The gap-fillers split into two different architectures, and this is the distinction people blur. Kueue is an admission controller. It sits in front and decides when a job waits, when it's admitted, when it's preempted. It manages quotas that queues can borrow and lend inside a cohort. But once a job is admitted, Kueue hands placement back to the default scheduler. Its all-or-nothing mode watches whether all the job's pods become ready within a timeout, and if they don't, it evicts and requeues the whole job.
Bouncer, not taxi driver.
Volcano is the taxi driver. It runs its own scheduler and does the placement itself, with gang scheduling, queue quotas and topology-aware placement built in. Kueue admits jobs. Volcano places them. Different layers of the same stack, honestly — you even see them paired.
And Kubernetes itself just closed this gap, didn't it.
Quietly, yes. Version one point three seven, released end of August, graduated the Workload and PodGroup APIs, which bring gang scheduling into the default scheduler itself. Off by default, though — you have to turn on the GenericWorkload feature gate on the API server, the controller manager and the scheduler. Three places, one flag each. Most operators will keep running Kueue or Volcano for a while yet, which is the usual pattern: the upstream fix ships, and the ecosystem that grew around the gap keeps the installed base.
And Ray, before we leave the scheduling layer — Ray is not doing this job, is it.
No, and the docs are explicit about it. Ray does not manage host operating systems, bare-metal networking, or physical server provisioning. Ray schedules Python tasks and actors — it's a compute layer, not an infrastructure layer. What you actually deploy is the KubeRay operator on Kubernetes, which gives you three objects. RayCluster handles lifecycle, autoscaling and fault tolerance. RayJob creates a cluster, submits a job, and can delete the cluster afterward — very nice for ephemeral bursts. RayService is a RayCluster plus a Ray Serve graph with zero-downtime upgrades.
KubeRay needs a queue too, doesn't it. It doesn't solve all-or-nothing on its own.
It integrates with Volcano, YuniKorn and Kueue for that. Ray assumes someone below it has solved placement, which is a running theme in this whole stack.
So the pattern in the wild.
The consensus is remarkably consistent across the national labs. A Swiss supercomputing centre paper from this spring put it plainly — large-scale pre-training with data parallelism and synchronous communication has fit naturally on HPC clusters run by queue-based workload managers. They keep pre-training and fine-tuning on Slurm, and run inference, agentic systems and RAG on Kubernetes. And they put fine-tuning on Slurm too, not because it's a natural fit, but because hosting it on both would mean duplicating the ugly work — debugging GPU-to-GPU communication, managing shared dataset access.
One pile of ugly work, not two.
A UK national service paper from August said Kubernetes is not considered a replacement for batch scheduling systems, and they expect Slurm to schedule the largest tenants and partitions. And on the other side of the coin, the CNCF's own survey from January found sixty-six percent of organizations hosting generative models use Kubernetes for some or all of their inference. Nobody's pattern is one tool. It's two tools and a line drawn between them.
And the people who refuse to choose.
Hybrid exists, and it costs. SchedMD's Slinky project runs Slurm inside Kubernetes, and lets Slurm schedule Kubernetes pods through a bridge. A shared node runs either native Slurm work or bridged Kubernetes work, never both at once. NERSC does something elegant — they run Slurm's controller and accounting daemon as Kubernetes deployments, so when a node dies, Kubernetes just reschedules the brain of the batch system.
The batch system that can't be rescheduled, rescheduled by the thing it looks down on.
But SchedMD's own talk lists the drawbacks. Kubernetes workloads run outside Slurm's view, and prioritizing between the two systems is difficult. Two schedulers in one cluster is a real cost, not a checkbox.
Well, before we get into all that, I believe your mother has a segment for us.
Oh, wonderful. Go ahead, Mum.
Hello dear, it's me, Dorothy, with Dorothy's History of Toast.
In eighteen sixty-one, Mrs Beeton's Book of Household Management has a recipe for a toast sandwich. One slice of toast between two slices of bread. Recommended for invalids.
You'd think toast would be a comfort, but no, it turns out it's mostly for people who are already poorly. That's the history of toast for you, dear. Things mostly don't work out.
Anyway, I've got a loaf proving on the radiator, so I'd better go. Bye bye, sweetheart.
A toast sandwich. Two pieces of bread doing nothing around a piece of toast.
Invalids. Anyway — topology. You mentioned topology-aware placement for Volcano and Kueue, and I don't want that slid past, because it feels like the underrated half of scheduling.
It matters as much as raw GPU count, and I mean that literally. Slurm reads your physical network layout from a topology config — leaf switches, spine switches, core fabric — and it prioritizes allocations inside the same leaf switch. Why? InfiniBand hop count. If your eight GPUs all hang off one leaf switch, they're one hop from each other. Split them across two spines and now every gradient exchange crosses the core fabric, and the bisection bandwidth of your core becomes the ceiling on the whole job.
Volcano does topology-aware placement, Kueue has its Topology-Aware Scheduling mode. The point for a first-time operator: when someone tells you their cluster has two thousand GPUs, the number that matters is how many of those two thousand are within one hop of each other. That's your actual machine.
Which is a good bridge downward. The scheduler decides which GPUs you get. The next question is how fast they can talk once you have them — and that's where the picture gets much less friendly.
NCCL. Pronounced "Nickel," which took me an embarrassingly long time to learn. It's NVIDIA's standalone library of collective routines — all-reduce, all-gather, reduce, broadcast, reduce-scatter, plus any point-to-point send and receive pattern you want. Optimized for PCIe, NVLink, NVSwitch, and InfiniBand verbs, with plain TCP sockets as the fallback nobody wants. Any number of GPUs, one node or many, single or multi-process. Current release landed just this week.
And AMD's mirror of it.
RCCL, pronounced "Rickle." Same collective set, optimized for PCIe, xGMI — that's AMD's intra-node link — and InfiniBand or TCP. Ring and tree algorithms. It's a port of NCCL in origin, and that word "port" is going to do a lot of work for us in about two minutes.
Beneath the libraries, the wire. NVLink.
NVLink is the physical substrate that makes NCCL fast inside a node. Announced back in March twenty fourteen. It's a wire-based, multi-lane, near-range link — a device can carry multiple NVLinks, and for small GPU counts the lanes give you an all-to-all mesh with no central hub. Since twenty eighteen it's packet-switched, with a central NVSwitch serving up to thirty-two two-lane ports per chip. And the clever bit on NVLink four point zero — the switch itself can do simple computation. Sum, broadcast, via the SHARP accelerator. The switch does part of the reduction instead of just forwarding bytes, which is communication work you don't have to do at the endpoints.
The switch doing arithmetic. Herman, you've gone quiet and shiny.
I have. A switch that computes is just — it's offloading the exact operation the network exists to carry. Sorry. Anyway, the vendor-neutral corner of this world: Intel oneCCL, and the OpenUCX project's pair, UCX for transport and UCC for collectives. Those are the escape hatch, and I'll come back to why that word is doing optimistic work.
Tuning. You said tuning is a discipline. I assumed it was a checkbox.
Nothing in this layer is a checkbox. NCCL can run its communication operations on up to sixty-four CTAs — cooperative thread arrays — simultaneously, as of the two point two seven release. And NVIDIA's own tuning guidance says raising CTA counts above the defaults often improves the individual operation's performance, but can hurt the overall workload. The knobs interact with your compute. More threads talking means fewer threads computing, and the balance is workload-specific.
The classic optimization story: the benchmark improves, the job slows down.
Now. The question everyone actually arrives with. Can you mix AMD and NVIDIA in one cluster?
My guess before you answer: the scheduler says yes and something below it says no.
Your guess is exactly the shape of it. The scheduler layer is vendor-neutral. Slurm and Kubernetes will happily hand out AMD nodes and NVIDIA nodes side by side — a node is a node. The break happens one layer down, at the collective, and the best documentation of it is an exchange on AMD's own issue tracker. A user was trying to run a collective job spanning RCCL and NCCL across AWS instances of the two vendors, getting socket errors that changed with every version combination. AMD's maintainer answered, and I'll quote him because the flatness is the content: "Sorry — even though RCCL is a port of NCCL, there's a lot of under-the-hood changes that prevent heterogenous usage of RCCL and NCCL across a cluster."
And then asked directly whether it could be run at all.
"No. This would not be supported." Five words, no ambiguity. Asked about UCX as a workaround: "UCX might work if you have different nodes with different hardware, but I'm not sure if anyone has tested this." Might work. Not sure anyone has tested it. That is the state of the vendor path in late twenty twenty-six.
Theoretically supported, in the way a rickety bridge is technically a crossing.
That's the UCC situation. One of the OpenUCX maintainers wrote that UCC can theoretically support collective communication across NVIDIA and AMD GPUs in a single workload — but with restrictions. Only two of its transports work; the others are incompatible because of non-homogeneous memory and can deadlock. For reduction collectives, every rank's local buffers have to match memory type, and mismatches don't fail gracefully, they deadlock. You're writing code on top of a library whose documented pitfall is hanging.
The research answer.
HetCCL, a preprint from this January. Its opening claim is that parallel training across GPUs from different vendors remains infeasible because of the incompatibility of their communication backends, and it presents itself as the first work enabling transparent use of all multi-vendor GPUs in a heterogeneous cluster — no changes at driver, runtime, compiler or application level. It unifies the vendor backends and adds RDMA across vendors, so existing PyTorch parallel code runs unchanged.
Preprint meaning nobody ships it.
Meaning I've seen no evidence it's in a production framework. But the paper's framing of why clusters end up mixed is the practically useful part, and I'd tattoo it on the inside of every procurement officer's eyelids: most organizations expand their clusters by acquiring GPU systems in a piecemeal fashion. Incremental procurement — keep the old hardware running, add the new generation when budget allows. Nobody plans a heterogeneous cluster. Everyone ends up with one.
By year two, every cluster is a museum.
The market numbers explain the shape of it, roughly eighty-eight percent NVIDIA, twelve percent AMD. Almost nobody buys AMD first, but plenty of places inherit some, or buy a few for a specific price point. So the practical workaround today is partition by vendor. Separate jobs, separate queues, separate partitions on the AMD side and the NVIDIA side. And if you must cross the boundary, treat it as a data-parallel boundary at most — exchange data as ordinary network traffic — never as a collective boundary.
Same vendor, different generations. This one's friendlier?
Workable, but it costs you, and the costs come in two currencies. The first one is structural: NCCL won't form a single flat communication ring across mixed NVLink generations — an A100 and an H100 speak different link revisions, and the topology discovery doesn't bridge them into one ring. The workaround, and I'll flag that this comes from a third-party explainer rather than NVIDIA's own docs, is to split the communicator and run separate rings per hardware generation.
Which means?
You manage two topologies instead of one. Your topology overhead doubles, your code has to be aware of the split, and every time a node joins or leaves, you're reasoning about two ring structures. The claim that NCCL refuses one ring across generations isn't in NVIDIA's documentation I've seen, but it's consistent with how NCCL discovers topology, so I'd treat it as reliable-with-an-asterisk.
The second currency.
Throughput. And here's the encouraging number. A PyTorch Foundation talk this year ran stock PyTorch — no custom code, FSDP and HSDP — across H100, H200, B200 and B300 nodes in a single training job. Heterogeneous mode achieved seventy-six to ninety-four percent of an equivalently sized homogeneous cluster, depending on model size and communication intensity, and model convergence was not impacted.
Seventy-six to ninety-four. That's... better than I'd have bet.
It surprised me too. The pitch in the deck is exactly the trade: customers with mixed fleets can use all their available capacity in one training job instead of leaving non-matching instances idle. Sitting at seventy-six percent of homogeneous is far better than one hundred percent of idle. And same-generation mixing, H100 plus H200, is the easy case — same NVLink generation, memory differences only.
So the real cost of heterogeneity isn't throughput, it's something sneakier.
You've read ahead. There's a paper from October on production traces from Alibaba's GPU clusters, and it names a failure I'd never seen named: ineffective occupancy. Even when GPU capacity is sufficient and placement is complete, fifty-two point seven percent of execution records never became ready. The GPUs were allocated, occupied, billed — and never produced useful computation.
Half the records. On a production fleet the size of Alibaba's.
Half. And their fix is interesting because of what drives it — a readiness-aware scheduler using just nine attributes observable at admission time, and the feature importance is dominated by job profile, duration and GPU model. Which is to say: whether your job will actually run is predicted largely by which generation of GPU it lands on. The scheduler cut ineffective occupancy from about forty-four percent to twenty-seven, and raised effective coverage of large requests, the eight-GPU-and-up jobs, from forty-six percent to sixty-three.
The mixed-generation cluster doesn't just run slower. It fails to start, quietly, half the time.
That reframed the whole heterogeneity question for me. People ask "how much throughput do I lose mixing generations" and the honest answer includes a second clause: and how often does the job never actually begin.
Which lands us on the thing Daniel's really probing at with the lock-in question. Because the folklore says the lock-in is the orchestrator — you pick Kubernetes, you're married to an ecosystem.
The folklore has it backwards. Kubernetes, Slurm and Ray are vendor-neutral. All three will schedule AMD and NVIDIA nodes side by side without complaint. The lock-in lives one layer down, in the collective library, and it doesn't announce itself as lock-in. It announces itself as an error message. One socket warning about a truncated message can end your heterogeneous ambitions for good, because the fix isn't configuration, it's a maintainer saying no.
The new operator budgets for GPUs, then networking, and forgets the software layer is the actual moat.
That's where it breaks, all right.
I've got two cards at home doing this right now, Herman. Different NVLink generations, same box, and they will not form a communicator. The library reports a generic initialization failure. Nothing about why. I found the actual reason on a forum at two in the morning, in a reply from somebody with a hedgehog avatar, that the two cards disagree about which link to use. I'd been through the driver, the permissions, the cable. It was none of it.
Generic failure, two-line forum post, hedgehog avatar. The whole support model in one screenshot.
The cards are still in the machine, by the way. It runs everything else fine. I do the inference work on whichever card answers first, and the box sits under the desk next to the amplifier, warming my feet, which is the only use it has made of NVLink yet. I did enough of that in the eighties, warming rooms with kit that wouldn't talk to itself. Corn was three sentences into his slow answer earlier and I had already trimmed a cough out of it. Anyway.
The fellow who sold me the second card — spent eleven years buying from him, never once got a padded envelope from the man, always the same recycled box with somebody else's name on it — insisted the two would work together. Quote, they're the same family, he said. They are not the same family. I have thirty shekels of forum evidence that says otherwise.
Did you go back to him with it?
No point. He retired in September. His nephew runs the counter now and offers me financing. Thirty shekels a month, he says, for the card that won't speak to its neighbour. I told him I'd keep the cards where they are. They match the amplifier. And I mean to see whether the next NCCL release fixes the ring before I touch anything.
Eleven years of recycled boxes, and the one time you needed him to be right.
That's shops for you. Give us two minutes, I've got a level drifting on Herman's channel.
Don't touch the gain, it was deliberate. Thirty shekels a month for a card that won't talk to its neighbour is the most honest financing structure in the whole GPU economy.
It's a support contract, technically. The support being a forum post by a hedgehog.
Which is the bit I keep coming back to — the layer that locks you in doesn't even have the courtesy to tell you it's locking you in.
The one thing, if you take one thing from this episode: the scheduler is a solved problem with several legitimate answers. The real constraints live in the communication layer, and that's the layer you should be budgeting for — the software, not just the silicon.
Sharpening it by one notch: before you sign anything, ask the vendor what error message you'll get when you add their next generation to your existing fleet. The answer tells you everything. A number means they've thought about it. Silence means you'll be the hedgehog's next reply.
The open question I'd leave dangling is whether HetCCL or something like it ever makes it into a production framework — because if it does, the whole piecemeal-procurement story changes. And whether the gang scheduling that graduated into Kubernetes in one point three seven ever actually gets switched on by default, or whether Kueue and Volcano just become permanent furniture.
And the GPU Operator's roadmap item — DRA integration — is the one to watch there, since it moves GPU scheduling closer to the core resource model.
Producer credit where it's due: Hilbert Flumingtop, who trims coughs mid-sentence and answers first with whichever card is listening. For more along these lines, there's episode two, Local STT For AMD GPU Owners; episode seventeen, Cloud Render Superpowers; and episode eighteen, Beyond the GPU. This has been My Weird Prompts, the human-AI collaboration podcast. If today's two-layer map earned its keep, the review button on your podcast app is right there, and it costs less than thirty shekels.